2026年杀菌和高水平消毒:新的和新兴的主题
Emily Sickbert-Bennett1, Erica S Shenoy2, David J Weber1
1Department of Infectious Diseases, UNC School of Medicine, Chapel Hill, NC, USA; Infection Prevention, UNC Health, Chapel Hill, NC, USA.
Infectious disease clinics of North America
|March 11, 2026
概括
医疗器械的适当杀菌和高水平消毒 (HLD) 对于防止感染传播至关重要. 本指南更新了光内镜和超声波探针的挑战和新兴主题.
科学领域:
- 预防和控制感染的预防和控制.
- 医疗设备再加工 医疗设备再加工
- 医疗流行病学 医疗流行病学
背景情况:
- 医疗器械加工中的缺陷增加了感染传播的风险.
- 绝育和高水平消毒 (HLD) 对患者安全至关重要.
- "2025年多社会指南"解决了当前的绝育和HLD挑战.
研究的目的:
- 为医疗器械提供关于绝育和HLD的最新信息.
- 扩展设备再处理中的新兴主题.
- 为应对与光照内镜和超声波探针相关的特定挑战.
主要方法:
- 审查和综合目前关于绝育和HLD的证据.
- 包括新兴主题,如镜和ATP测试.
- 专注于特定的设备类型:发光内镜和超声波探针.
主要成果:
- 提供了关于绝育和HLD实践的最新信息.
- 讨论了包括镜和ATP在内的新话题,用于清洁性评估.
- 扩展了对表面和内腔超声波探针的消毒指南.
结论:
- 遵守最新的绝育和HLD指南对于预防感染至关重要.
- 新兴技术和特定设备的考虑需要持续关注.
- 必须了解和应用各种医疗器械的适当消毒水平.
相关概念视频
Cleaning, Sterilization, and Disinfection
12.6K
Cleaning, disinfection, and sterilization are the methods that help to break the infection chain and prevent disease.
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
12.6K
Methods of Sterilization II: Chemical Methods
10.2K
In healthcare, the chemical method of sterilization uses chemical sterilants to treat surgical instruments and medical supplies to help prevent the transmission of infectious pathogens to patients. Due to heat sensitivity, most medical supplies and equipment should not be exposed to high temperatures. These parts include rubber, plastic, glass, and other similar elements.
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
10.2K
Methods of Sterilization I: Physical Methods
25.0K
As used in a healthcare facility, sterilization destroys all microorganisms through physical or chemical methods. The physical method includes steam, dry heat, boiling water, and radiation.
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
25.0K
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
1.4K
Radiation and filtration are essential tools for microbial control, targeting microorganisms through distinct mechanisms. Radiation eliminates microbes by damaging their DNA, either killing them or inhibiting their growth. Based on wavelength, radiation is classified into two types: nonionizing and ionizing radiation.Non-ionizing radiation, such as UV radiation (200–400 nm), is absorbed by DNA, causing defects that effectively disinfect surfaces, air, and water, including safety cabinets.
1.4K
Chemical Agents for Microbial Control
1.4K
Chemicals play important roles in controlling microbial growth by targeting microbial structures and functions as sanitizers, antiseptics, disinfectants, and sterilants.Alcohols are commonly used sanitizers, effectively disrupting lipid membranes, which compromises cell integrity. They are also used as antiseptics and disinfectants due to their rapid action and versatility.Phenols and their derivatives phenolics , known for denaturing proteins and disrupting cell membranes, are particularly...
1.4K
Physical Methods for Controlling Microbial Growth: Temperature
1.4K
Heat is a widely used method to control microbial growth by targeting and denaturing cellular proteins, thereby killing or inactivating microbes. This method's effectiveness is quantified using parameters such as the thermal death point (TDP), thermal death time (TDT), and decimal reduction time (D value). TDP represents the lowest temperature at which all microorganisms in a liquid suspension are eliminated within 10 minutes, whereas TDT is the time necessary to achieve sterilization at a...
1.4K