从平衡心脏血池评估的左心室跳动到跳动的表现,使用计算机核探测器使用计算机核探测器进行评估
Circulation
|January 1, 1981
概括
一个新的计算机化非成像闪探测器准确而可靠地测量了连续的节拍对节拍左心室喷射率. 这种便携式设备提供了一种可行的实时心脏性能评估方法,没有心电图门.
科学领域:
- 心脏病学 心脏病学
- 医疗成像医学成像
- 生物医学工程 生物医学工程
背景情况:
- 持续对左心室 (LV) 性能进行节拍评估对于理解心脏病理生理学至关重要.
- 现有的方法在实时数据采集方面可能是有限的,或者需要心电图门.
研究的目的:
- 评估一种新型计算机化非成像闪光探针的可行性,准确性和可重复性,用于持续的节拍对节拍LV射出分数 (LVEF) 评估.
- 为了确定探头是否可以在没有心电图门的情况下生成实时LV体积曲线.
主要方法:
- 在71名患者中使用了便携式,非成像的闪探针来评估LV性能.
- 计算机算法和操作员例程为LV和背景感兴趣区域标准化了探头定位.
- 从探头数据计算出节拍对节拍的LVEF,并与使用多晶体闪相机进行的第一通研究进行比较.
主要成果:
- 探测器证明了高相关性 (r = 0.92) 与第一通过研究在广泛的LVEF值 (15-81%).
- 在初始和重复分析 (r = 0.97) 和研究 (r = 0.94) 之间发现了良好的一致性.
- beat-to-beat LVEF测量的绝对可变性为 +/- 5.9% (± 2 SD). 没有任何变化.
结论:
- 计算机化非成像闪探测器是一种可行的,准确的,可重复的工具,用于连续的节奏到节奏的LVEF监测.
- 这种技术为调查需要节拍心脏数据的病理生理学条件提供了可靠的方法.
- 便携性和不需要心电图门的特性增强了其临床实用性.
更多相关视频
相关概念视频
Pulse rhythm
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Heart Sounds
Heart sounds are generated by the turbulence in blood flow due to the closing of heart valves. These sounds are best perceived slightly away from the valves, where the blood flow disseminates the sound.
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Imbalances in Cardiac Output
The heart's primary function is to pump blood throughout the body, maintaining a balance between blood sent out (cardiac output) and blood returning (venous return). If this balance is disrupted, it can result in congestive heart failure (CHF), a severe condition where the heart becomes an inefficient pump, leading to inadequate blood circulation.
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Assessment of the Cardiovascular System III: Palpation
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of the Cardiovascular System IV: Auscultation
Cardiac auscultation is a clinical skill used to assess heart function and detect abnormalities. It involves listening to heart sounds at specific anatomical locations through a stethoscope.
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.