相关实验视频
Updated: Jul 10, 2026

10:35
Bringing the Visible Universe into Focus with Robo-AO
Published on: February 12, 2013
哈勃太空望远镜 (HST) 在Shoemaker-Levy 9彗星上进行观测活动
H A Weaver1, M F A'Hearn, C Arpigny
1Space Telescope Science Institute, Baltimore, MD 21218.
概括
哈勃望远镜对彗星P/Shoemaker-Levy 9的观测揭示了彗星分裂后的连续彗星活动和碎片化. 这些事件表明有不同的核,而不仅仅是碎片,可能是由木星的磁层触发的.
科学领域:
- 天文学 天文学
- 行星科学 行星科学
- 彗星科学 彗星科学
背景情况:
- 彗星P/Shoemaker-Levy 9 (SL9) 分裂并撞击木星.
- 哈勃太空望远镜 (HST) 提供了对彗星碎片的系统观测.
研究的目的:
- 分析哈勃望远镜对彗星SL9.9的观测结果.
- 为了确定碎片大小,彗星活动和碎片化行为.
- 调查观察到的排放的潜在原因.
主要方法:
- 宽场行星摄像头图像的解卷,以估计碎片直径.
- 通过观察内部昏迷来分析彗星活动.
- 用光谱观测来检测排放 (例如,离子,连续,OH).
主要成果:
- 碎片直径估计在<1至4公里之间.
- 持续的,微弱的彗星活动观察到1994年6月下旬.
- 观察到核分裂后的碎片化,挑战了碎片群假设.
- 检测到离子和连续辐射爆发,可能是由于木星磁层中的静电电荷.
- 确定H2O生产速率的上限,不表明缺水对象.
结论:
- 彗星SL9碎片拥有不同的核,并表现出持续的活动.
- 与木星磁层的相互作用可能引发了能量事件.
- 哈勃望远镜的观测提供了关于彗星动态和组成的关键数据.
相关概念视频
Kepler's Second Law of Planetary Motion
In the early 17th century, German astronomer and mathematician Johannes Kepler postulated three laws for the motion of planets in the solar system. His first law states that all planets orbit the Sun in an elliptical orbit, with the Sun at one of the ellipse's foci. Therefore, the distance of a planet from the Sun varies throughout its revolution around the Sun.
While in an elliptical orbit, the total energy of the planet is conserved. Therefore, the planet slows down when it is at apogee and...
While in an elliptical orbit, the total energy of the planet is conserved. Therefore, the planet slows down when it is at apogee and...
Kepler's Third Law of Planetary Motion
In the early 17th century, German astronomer and mathematician Johannes Kepler postulated three laws for the motion of planets in the solar system. In 1909, he formulated his first two laws based on the observations of his forebears, Nikolaus Copernicus and Tycho Brahe. However, in 1918, he published his third law of planetary motion, which gives a precise mathematical relationship between a planet's average distance from the Sun and the amount of time it takes to revolve around the Sun. It...
Detection of Black Holes
Although black holes were theoretically postulated in the 1920s, they remained outside the domain of observational astronomy until the 1970s.
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
IR Spectrometers
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Atomic Emission Spectroscopy: Lab
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...

