用于快速确定血液中乳酸盐度的基质特异性电极的使用和临床重要性
J Aduen1, W K Bernstein, T Khastgir
1Department of Medicine, Sinai Hospital of Baltimore, MD 21215-5271.
JAMA
|December 7, 1994
概括
一个新的电极准确地测量了血液中的乳酸. 在健康人群中,乳酸盐水平升高 (>4 mmol/L) 是罕见的,在住院患者中可能表明严重疾病或死亡风险.
科学领域:
- 临床化学 临床化学
- 生物医学工程 生物医学工程
- 关键护理医学 关键护理医学
背景情况:
- 快速准确地测量循环中的乳酸对于患者的诊断和预后至关重要.
- 现有的乳酸测定方法可能耗时,限制了它们在急性护理环境中的实用性.
研究的目的:
- 评估一种新型电压计,酶计,基质特异性电极的准确性和临床意义,用于快速测量乳酸.
- 为了确定血中乳酸盐度升高的诊断和预后值.
主要方法:
- 一项前性研究涉及1218名患者和对照人群,涉及各个医院 (ICU,ED,普通病房).
- 对新电极的验证与两种已建立的实验室参考方法相比.
- 在不同患者群体中分析血液中乳酸盐度,以评估临床重要性.
主要成果:
- 新的电极在偏差,精度和相关性 (r值高达0.98) 方面与参考方法有很好的一致性.
- 与正常患者和普通病房患者相比,ICU和ED患者的乳酸盐度升高 (> 4 mmol/L) 显著更高 (P < .001).
- 乳酸盐水平>4 mmol/L显示高特异性 (98.2%) 预测ED患者入院,高特异性 (96%) 预测非潜在性住院患者的死亡率.
结论:
- 新的电比电极提供了精确和准确的乳酸测量.
- 血液中乳酸盐度超过4mmol/L在健康或非危急病患者中不常见,并表明潜在的担忧.
- 乳酸盐水平升高 (>4 mmol/L) 与临界病患者和非临界病患者住院患者的预后不佳有关.
相关概念视频
Electrodes: Overview
Electrochemical measurements are conducted in an electrochemical cell composed of various components that control and measure the current and potential. One fundamental component is electrodes, conductive materials that enable electron transfer reactions at their surfaces.
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...
Potentiometry: Types of Electrodes
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Electrogravimetric Analysis: Overview
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
To test the completeness of the...
Amperometry: Overview
Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
Effects of EDTA on End-Point Detection Methods
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Electrodeposition
Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
Electrodeposition can...