Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Intraoperative computed tomography guided neuronavigation: concepts, efficiency, and work flow.

C Matula1, K Rössler, M Reddy

  • 1Neurosurgical Department, University of Vienna, Austria. Christian.Matula@univie.ac.at

Computer Aided Surgery : Official Journal of the International Society for Computer Aided Surgery
|February 23, 1999
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Inhibiting Anti-angiogenic VEGF165b Activates a Novel miR-17-20a-Calcipressin-3 Pathway that Revascularizes Ischemic Muscle in Peripheral Artery Disease.

Research square·2023
Same author

Retraction Note to: Does platelet size correlate with function in patients undergoing cardiac surgery?

Intensive care medicine·2023
Same author

A third-line antiretroviral therapy register to track patient clinical and virological outcomes.

South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde·2022
Same author

A third-line antiretroviral therapy register to track patient clinical and virological outcomes.

South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde·2022
Same author

A multicenter prospective observational study on the use of type and screen method versus conventional type and crossmatch policy for pre-transfusion testing in the Indian population.

Immunohematology·2022
Same author

Positive direct antiglobulin tests in cancer patients hospitalized with COVID-19: A brief report from India.

Transfusion clinique et biologique : journal de la Societe francaise de transfusion sanguine·2022
Same journal

Towards the clinical integration of an image-guided navigation system for percutaneous liver tumor ablation using freehand 2D ultrasound images.

Computer aided surgery : official journal of the International Society for Computer Aided Surgery·2015
Same journal

Novel method for setting up 3D navigation system with skin-fixed dynamic reference frame in anterior cervical surgery.

Computer aided surgery : official journal of the International Society for Computer Aided Surgery·2015
Same journal

Numerical simulation of blood flow and plaque progression in carotid-carotid bypass patient specific case.

Computer aided surgery : official journal of the International Society for Computer Aided Surgery·2015
Same journal

Prediction of post-operative range of motion using intra-operative soft tissue balance in total knee arthroplasty with navigation.

Computer aided surgery : official journal of the International Society for Computer Aided Surgery·2015
Same journal

A comparison of two surgical approaches in functional neurosurgery: individualized versus conventional stereotactic frames.

Computer aided surgery : official journal of the International Society for Computer Aided Surgery·2015
Same journal

Robot-assisted primary cementless total hip arthroplasty with a short femoral stem: a prospective randomized short-term outcome study.

Computer aided surgery : official journal of the International Society for Computer Aided Surgery·2015
See all related articles

Integrating an intraoperative computed tomography (CT) scanner with neuronavigation significantly improves accuracy in image-guided surgery by addressing brain shift. This closed-system approach saves substantial time and enhances patient outcomes.

Area of Science:

  • Neurosurgery
  • Medical Imaging
  • Surgical Navigation

Background:

  • Frameless stereotactic neuronavigation accuracy degrades due to brain and/or lesion shift.
  • Image-guided surgery is crucial in neurosurgery but faces accuracy challenges.
  • Existing neuronavigation systems are susceptible to intraoperative anatomical changes.

Purpose of the Study:

  • To evaluate the advantages of integrating an intraoperative computed tomography (CT) scanner with a neuronavigation system.
  • To provide an integrated solution for improved accuracy in image-guided neurosurgery.
  • To assess the impact of intraoperative imaging on surgical workflow and patient outcomes.

Main Methods:

  • Integration of a Philips Tomoscan M CT scanner with the Philips EasyGuide neuronavigation system.

Related Experiment Videos

  • Evaluation in 20 neurosurgical cases (15 microsurgical, 5 endoscopic).
  • Utilized a specially developed scanner table and radiolucent head fixation for high-quality intraoperative imaging.
  • Main Results:

    • Successful integration of the intraoperative CT scanner in all procedures.
    • Significantly improved accuracy in image-guided surgery (1.6:1.22.2).
    • Demonstrated time savings of approximately 55 hours per operating room over 6 months.
    • Enabled intraoperative identification of residual tumor in ~20% of cases.
    • Effectively compensated for intraoperative brain and/or tumor shifts.

    Conclusions:

    • The combination of intraoperative CT and neuronavigation offers an integrated solution to improve accuracy and efficiency in image-guided neurosurgery.
    • This closed-system approach enhances workflow, reduces treatment time, and improves clinical outcomes.
    • Intraoperative imaging provides critical updates, enabling precise tumor resection and quality checks.