Related Experiment Video
Updated: Aug 19, 2026

Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Determination of niacin in infant formula and wheat flour by anion-exchange liquid chromatography with solid-phase
D E LaCroix1, W R Wolf, J T Vanderslice
1U.S. Department of Agriculture, Beltsville Human Nutrition Research Center, Food Composition Laboratory, MD 20705-2350, USA.
Abstract:
Niacin content must be included on food labels of infant formula products and bakery products containing enriched flour. Liquid chromatographic (LC) determination of niacin in complex food matrixes is complicated by the presence of endogenous compounds that absorb at the commonly used wave-length of 260 nm. Also, the presence of particulate matter in the standard sulfuric acid extraction procedure results in reduced life of LC columns and precolumns. A simple, rapid, solid-phase extraction (SPE) procedure for separation and cleanup of niacin from a complex food matrix digest has been developed. By using a vacuum manifold with the SPE column system, multiple samples can be processed quickly and efficiently for LC analysis, compared with gravimetric column cleanup. Sulfuric acid sample digest is passed over an aromatic sulfonic acid cation-exchange (ArSCX-SPE) or a sulfonated Florisil SPE column. Niacin is eluted with 0.25M sodium acetate-acetic acid, pH 5.6 buffer in vacuo. LC chromatograms of the resulting eluate are free of interference from other components absorbing at 260 nm at the retention time of niacin. Validation of the method was obtained from agreement of analytical results on available reference materials. For both SPE methods, values for niacin in SRM 1846 Infant Formula (milk-based powder) were within uncertainty ranges of the certified value. Use of several calibration procedures (the LC computer program, a peak area response graphic standard curve, or the method of standard additions) with both SPE procedures resulted in niacin values for 3 RM-Wheat Flours (not certified for niacin) in agreement (90-105%) with their respective values reported in the literature. Several commercial wheat flours showed a broad 260 nm interference, resulting in high niacin values. Niacin recoveries from spiked soy-based liquid infant formulas ranged from 95-107% with the ArSCX-SPE column. Calibration curves of niacin were linear up to 400 micrograms/mL, with a detection limit of 0.2 microgram/mL.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
08:54Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025