Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

281
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
281
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

279
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
279
Computed Tomography01:10

Computed Tomography

8.0K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
8.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

To iMAR or not to iMAR: Quantitative impact of MAR algorithms on image quality in a phantom study.

Radiography (London, England : 1995)·2025
Same author

Novel iterative reconstruction method with optimal dose usage for partially redundant CT-acquisition.

Physics in medicine and biology·2015
Same author

Determination of the Middle Cerebral Artery Occlusion Length in Acute Stroke: Contribution of 4D CT Angiography and Importance for Thrombolytic Efficacy Prediction.

Clinical neuroradiology·2014
Same author

[Influence of atracurium on cardiovascular parameters in horses undergoing vitrectomy during general anaesthesia, and on recovery duration and quality].

Tierarztliche Praxis. Ausgabe G, Grosstiere/Nutztiere·2013
Same author

Sinogram affirmed iterative reconstruction in head CT: improvement of objective and subjective image quality with concomitant radiation dose reduction.

European journal of radiology·2013
Same author

Assessment of thermal sensitivity of CT during heating of liver: an ex vivo study.

The British journal of radiology·2012
Same journal

ESR Essentials: pelvic floor imaging-practice recommendations by the European Society of Urogenital Radiology.

European radiology·2026
Same journal

STIR or T2-Dixon? A false dilemma in musculoskeletal MRI.

European radiology·2026
Same journal

ESR Essentials: uterine cancers-practice recommendations by the European Society of Urogenital Radiology.

European radiology·2026
Same journal

Adjunctive quantification for more reproducible amyloid PET interpretation.

European radiology·2026
Same journal

APEX-NET: automated pancreatic evaluation network using early non-contrast CT.

European radiology·2026
Same journal

Temporal bone remodeling after venous stenting for pulsatile tinnitus: isolated dehiscence versus diverticulum.

European radiology·2026
See all related articles

Related Experiment Video

Updated: Jan 14, 2026

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
05:49

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization

Published on: February 23, 2024

1.3K

Efficient object scatter correction algorithm for third and fourth generation CT scanners.

B Ohnesorge1, T Flohr, K Klingenbeck-Regn

  • 1Siemens Medical Engineering, Department CTC 2, D-91301 Forchheim, Germany.

European Radiology
|March 23, 1999
PubMed
Summary
This summary is machine-generated.

This study introduces a fast, adaptable algorithm to correct scatter artifacts in computed tomography (CT) imaging. The method effectively reduces image artifacts like cupping and dark bands, improving image quality in both third and fourth generation CT systems.

More Related Videos

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
07:13

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities

Published on: October 27, 2023

1.6K
Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

8.4K

Related Experiment Videos

Last Updated: Jan 14, 2026

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
05:49

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization

Published on: February 23, 2024

1.3K
Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
07:13

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities

Published on: October 27, 2023

1.6K
Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

8.4K

Area of Science:

  • Medical Imaging
  • Radiological Physics
  • Computed Tomography

Background:

  • X-ray scatter in computed tomography (CT) causes artifacts such as cupping and dark bands, degrading image quality.
  • Artifact amplitude increases with scanned volume and slice width.
  • Existing anti-scatter collimation is insufficient in fourth-generation CT, necessitating numerical correction.

Purpose of the Study:

  • To present a computationally efficient and parameterizable correction algorithm for object scatter in CT.
  • To improve image quality by reducing scatter-induced artifacts in third and fourth generation CT systems.

Main Methods:

  • Developed a correction algorithm using convolution of projection data with a scatter convolution function.
  • The scatter convolution function is derived from simulations and measurements using differential scatter cross-section data.
  • The algorithm is parameterized for both third and fourth generation CT geometries.

Main Results:

  • The algorithm effectively corrects scatter artifacts in third-generation CT scanners.
  • Significant reduction of object scatter artifacts is achieved in fourth-generation CT scanners with poor collimation.
  • The method demonstrates low computational effort and flexible application across different body regions.

Conclusions:

  • The proposed algorithm provides an effective solution for reducing scatter artifacts in CT imaging.
  • It offers a valuable tool for enhancing image quality in both established and modern CT systems.
  • The parameterizable nature allows for broad applicability in clinical and research settings.