Related Experiment Video
Updated: Aug 28, 2026

Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
Published on: October 7, 2015
Core temperature monitoring of firefighters during hazardous materials training sessions
R Menze1, M J McMullen, L J White
1Emergency Medicine Residency Program, Akron General Medical Center, Ohio, USA.
Objective:
To determine core temperature (Tc) elevations in hazardous materials (HazMat) technicians wearing level-A fully encapsulated, chemically resistive suits (FECRSs) during training scenarios.
Design:
Cross-sectional, observational feasibility study with Institutional Review Board approval.
Setting:
HazMat training scenarios held during the summer of 1994. Weather conditions included both rainy and sunny days, with a mean ambient temperature of 75.8 degrees F (24.3 degrees C) (range 69-83 degrees F [20.6-28.3 degrees C).
Participants:
Nine male firefighters participating in training scenarios in the Midwestern United States.
Interventions:
Each volunteer swallowed a capsule containing a Tc sensor developed by the National Aeronautics and Space Administration. The capsule continuously monitored Tc and stored data in an ambulatory recorder worn under the level-A FECRS during training.
Results:
Mean age of the volunteers was 34 years, mean weight was 92.6 kg, and average baseline Tc was 36.7 degrees C (97.1 degrees F) (range 35.3-38.2 degrees C [95.5-100 degrees F]). Time in the FECRS averaged 25.4 minutes (range 14-35 minutes). All subjects demonstrated increased Tc while in the suit; the mean Tc increase was 0.8 degree C (1.4 degrees F) (range 0.2-1.3 degrees C [0.4-2.3 degrees F]). The Tc continued to increase during wet decontamination procedures and after suit removal. Mean heat storage values (delta Tcx LBMx 3.47 kJ) were calculated, and found to be moderately elevated to 3.6 kJ/kg (range 2.1-4.6 kJ/kg).
Conclusion:
These observations support the validity and significance of implementing prophylactic measures for firefighters using protective clothing. Simple protective measures include enforced time limitations, hydration, and efforts to minimize heat buildup by avoiding both direct sunlight and unnecessary time encapsulated in the suit.
More Related Videos
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
06:19Standardized Protocol For Monitoring Muscle Fatigue and Biomechanics In Amateur Cyclists Using Infrared Thermography
Published on: March 20, 2026
Related Concept Videos
Factors Affecting Body Temperature
Factors may include:
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...