Regional distribution centres

Journal of Sterile Services Management
|July 9, 1987
PubMed

Related Concept Videos

Regulated mRNA Transport02:22

Regulated mRNA Transport

In eukaryotes, transcription and translation are compartmentalized; an mRNA is first synthesized in the nucleus and then selectively transported to the cytoplasm for protein synthesis. Before transport, a pre-mRNA undergoes several steps of post-transcriptional modifications including splicing, 5' capping, and the addition of a poly-adenine tail. Various proteins bind to the pre-mRNA during these modifications. The mRNA transport takes place with the help of multiple proteins playing specific...
Regulated mRNA Transport02:22

Regulated mRNA Transport

In eukaryotes, transcription and translation are compartmentalized; an mRNA is first synthesized in the nucleus and then selectively transported to the cytoplasm for protein synthesis. Before transport, a pre-mRNA undergoes several steps of post-transcriptional modifications including splicing, 5' capping, and the addition of a poly-adenine tail. Various proteins bind to the pre-mRNA during these modifications. The mRNA transport takes place with the help of multiple proteins playing specific...
Regional Terms01:12

Regional Terms

Regional terms describe anatomy by dividing the body parts into different regions that contain structures involved in contributing similar functions. Using these terms helps increase the accurate description and identification of the particular region of interest or region affected by the disease.
Primarily, the human body has two major regions, the axial and appendicular regions. The axial region comprises regions from the head to the abdomen and makes up the central body axis. In contrast,...
Primary Distribution01:28

Primary Distribution

Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
Secondary Distribution01:25

Secondary Distribution

Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
Distribution Reliability and Automation01:25

Distribution Reliability and Automation

Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...