Evaluation of two electronic respiratory rate monitoring systems
Abstract:
Two electronic systems for monitoring respiratory rates in critical care patients were evaluated--one a system using impedance sensors and the other a system using thermistor sensors. The thermistor sensor, attached to a nasal cannula or air-entrainment mask, was connected to a sensitivity calibrating control and a digital display module. The impedance system consisted of three electrocardiogram chest leads connected to an identical digital display module. Each of 10 patients was simultaneously monitored by both systems; indicated rates from the two systems were then compared to a counted control rate to determine accuracy. Data were collected at 17 successive half-hour intervals. Analysis of variance of the data gave a significant F ratio for differences among the three methods of rate monitoring. The impedance system gave readings progressively higher and the thermistor system gave readings progressively lower than the counted control rates. This study indicates that this configuration for both impedance and thermistor sensing lacks the desired accuracy for respiratory rate monitoring but may be suitable for apnea alarms.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Respiratory Volumes and Capacities I
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: