Related Experiment Video
Updated: Oct 12, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Arterial oxygen values achieved by COPD patients breathing oxygen alternately via nasal mask and nasal cannula
Abstract:
Ten patients with known but clinically stable chronic obstructive pulmonary disease (COPD) were studied while breathing low-flow (1-2 L/min) supplemental oxygen by nasal cannula and by biflow nasal mask. Although the increase in inspired oxygen when breathing with the cannula has been documented, the nasal mask has not been tested by measurement of PaO2 change. The mean age of the group was 64.6 years, and their mean PaO2 was 54 +/- 10.5 torr while they were at rest and breathing room air. Patients were each given oxygen alternately with the mask and cannula, with no change in flowrate; time was allowed between the two for equilibration and return to baseline values. PaO2 values were compared by t test for nonindependent samples, which provided a t value of 1.893, with P = 0.09. Differences in measured arterial saturation (SaO2) and PaCO2 also proved to be insignificant when patients breathed via the two devices. The conclude that the nasal cannula and the biflow nasal mask produce comparable PaO2 in patients who may need low-flow supplemental oxygen at rest. The mask can be considered an alternative oxygen appliance if preferred by patients because of comfort.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: