Related Experiment Video
Updated: Aug 17, 2026

Vascular Balloon Injury and Intraluminal Administration in Rat Carotid Artery
Published on: December 23, 2014
Comparison of a continuous suture pattern with a simple interrupted pattern for enteric closure in dogs and cats: 83
D L Weisman1, D D Smeak, S J Birchard
1Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Ohio State University, Columbus 43210, USA.
Objective:
To describe and compare a simple continuous suture pattern with a simple interrupted pattern for enterotomy closure or end-to-end intestinal anastomosis.
Design:
Retrospective study.
Animals:
58 dogs and 25 cats that underwent enterotomy or intestinal resection and anastomosis.
Procedure:
Signalment, surgical procedure, suture pattern, suture material, confirmation of dehiscence, and follow-up were reviewed. Groups were compared by procedure (anastomosis or enterotomy) and by suture pattern.
Results:
57 animals underwent continuous closure; 26 had interrupted closure. Only polydioxanone or polypropylene suture materials were used. Overall, 81 (98%) animals had no signs of intestinal dehiscence and survived > 2 weeks. Two animals had confirmed dehiscence after foreign body removal, 1 of 57 (2%) after continuous closure, and 1 of 26 (4%) after interrupted closure.
Clinical Implications:
The simple continuous closure pattern is an acceptable alternative to simple interrupted closure for small intestinal anastomosis or enterotomy closure.