Related Experiment Video
Updated: Aug 12, 2026

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
Published on: December 9, 2010
NMRD assessment of Gd-DTPA-bis(methoxyethylamide), (Gd-DTPA-BMEA), a nonionic MRI agent
K Adzamli1, M P Periasamy, M Spiller
1Department of Medical Information Sciences, University of Illinois, Urbana, USA.
Rationale And Objectives:
Gd-DTPA-BMEA, a nonionic bis(methoxyethylamide) derivative of Gd-DTPA, is the active ingredient of OptiMARK, now awaiting FDA approval. In this study, we compare the relaxivities of Gd-DTPA-BMEA (OptiMARK) with those of the commercially available DTPA-based agents Gd-DTPA2- (Magnevist) and Gd-DTPA-BMA (Omniscan) at different field strengths (1/T1 nuclear magnetic relaxation dispersion (NMRD) profiles). In addition, we study how changes in structural attributes of small paramagnetic chelate complexes of Gd3+ ions influence 1/T1 NMRD profiles.
Methods:
1/T1 NMRD profiles of Gd-DTPA-BMEA (OptiMARK) were measured at 5 degrees and 35 degrees C and a set of values for the parameters that describe relaxation by Gd(3+)-proton magnetic dipolar interactions was obtained. The rotational (tau R) and the diffusional (tau D) correlation times for Gd-DTPA-BMA were adjusted for the 15% greater molecular weight of Gd-DTPA-BMEA. tau M (the resident lifetime of Gd(3+)-bound water) was obtained from available 17O NMR relaxation data. For tau S0 and tau V (the low-field relaxation time of the Gd3+ moment and its correlation time), Gd-DTPA-BMA values were taken as initial values and tau S0 refined as needed.
Results:
Although, at 35 degrees C, tau M is comparable for the two neutral agents and an order of magnitude longer than that for Gd-DTPA2-, the 1/T1 NMRD profiles of Gd-DTPA-BMEA are indistinguishable from those of Gd-DTPA2- and Gd-DTPA-BMA. A 40% increase in the value of tau S0 from Gd-DTPA2- is required for agreement of data and theory for Gd-DTPA-BMEA.
Conclusions:
Based on their 1/T1 NMRD profiles, the efficacy of the three agents should be identical in typical clinical MRI applications. The data can be fit reliably to theory, and differences in the fit parameters (and structure) have no effect on the three profiles at 35 degrees C. The relatively long values of tau M for the two neutral agents would only be of importance at low temperatures.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI

