Related Experiment Videos
[Biomechanical observation on unstable intertrochanteric fracture fixed by 130 degrees angled-plate]
Zhonghua Wai Ke Za Zhi [Chinese Journal of Surgery]
|June 1, 1997
Abstract:
We examined the stability of unstable intertrochanteric fracture fixed by 130 degrees angled-plate biomechanically, and the stress distribution of the plate. The results showed that after 300 times circle-loading test, the fracture stability was destroied. Stress concentration was observed on the plate, which was aggravated by circle-loading test. These confirmed the inproper biomechanical stature of the plate. Referring to the clinical review, we conclude that using angled-plate to fix unstable intertrochanteric fracture hardly yields satisfactory results, at least, early wight-bearing exercise should not be promoted.