Technical management of a pregnant patient undergoing radiation therapy to the head and neck
M B Podgorsak1, R J Meiler, H Kowal
1Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, NY 14263, USA. podgorsa@acsu.buffalo.edu
The fetal dose in a pregnant patient undergoing radiation therapy to the head and neck region was investigated. Implicit in this study was the design and evaluation of a shield used to minimize the fetal dose. To evaluate the fetal dose, a phantom was irradiated with the fields designed for this patient's therapy. The peripheral dose was measured for each field individually, both without and with a custom shield designed to be placed about the patient's abdominal and pelvic regions. The total dose at the location of the fetus over the course of this patient's radiation therapy was then estimated from peripheral dose rate measurements made at several points within the simulated uterus. With no shielding, the total dose within the uterus of the patient would have ranged from 13.3 cGy at the cervix to 28 cGy at the fundus. With the shield applied, the uterine dose was significantly less: 3.3 cGy at the cervix to 8.6 cGy at the fundus. In fact, at every measurement point, the peripheral dose with the shield in place was 30% to 50% of the dose without the shield. Some data suggest that the rate of significant abnormalities induced by irradiation in utero increases with increasing dose within the range of total peripheral doses incurred during most radiation treatment courses. It is therefore prudent to make reasonable attempts at minimizing the dose to the lower abdominal and pelvic regions of any pregnant patient. The shield designed in this work accomplished this goal for this patient and is flexible enough to be used in the treatment of almost all tumor volumes.
The fetal dose in a pregnant patient undergoing radiation therapy to the head and neck region was investigated. Implicit in this study was the design and evaluation of a shield used to minimize the fetal dose. To evaluate the fetal dose, a phantom was irradiated with the fields designed for this patient's therapy. The peripheral dose was measured for each field individually, both without and with a custom shield designed to be placed about the patient's abdominal and pelvic regions. The total dose at the location of the fetus over the course of this patient's radiation therapy was then estimated from peripheral dose rate measurements made at several points within the simulated uterus. With no shielding, the total dose within the uterus of the patient would have ranged from 13.3 cGy at the cervix to 28 cGy at the fundus. With the shield applied, the uterine dose was significantly less: 3.3 cGy at the cervix to 8.6 cGy at the fundus. In fact, at every measurement point, the peripheral dose with the shield in place was 30% to 50% of the dose without the shield. Some data suggest that the rate of significant abnormalities induced by irradiation in utero increases with increasing dose within the range of total peripheral doses incurred during most radiation treatment courses. It is therefore prudent to make reasonable attempts at minimizing the dose to the lower abdominal and pelvic regions of any pregnant patient. The shield designed in this work accomplished this goal for this patient and is flexible enough to be used in the treatment of almost all tumor volumes.
Related Concept Videos
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed.
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT