Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
Boltzmann analysis of CM waveforms using virtual instrument software
1Department of Physiology, University of Western Australia, Nedlands, Australia. rpatuzzi@cyllene.uwa.edu.au
Abstract:
We describe a modification to our technique for the rapid analysis of low-frequency cochlear microphonic (CM) waveforms in the basal turn of the guinea pig cochlea (Patuzzi and Moleirinho, 1998). The transfer curve relating instantaneous sound pressure in the ear canal to instantaneous receptor current through the outer hair cells (OHCs) is determined from the distorted microphonic waveform generated in the extracellular fluid near the hair cells, assuming a first-order Boltzmann activation curve. Previously, the analysis was done in real time using custom-built electronic circuitry. Here, the same task is performed numerically using virtual instrument software (National Instruments LabVIEW 4.1) running on a personal computer. The assumed theoretical function describing the CM waveform is Vcm = Voff + Vsat/[1 + exp[(Eo+Z.Po.sin(2pi f + phi(tot)))/kT]], where the six parameters are (i) a DC offset voltage (Voff); (ii) the frequency of the sinusoidal stimulus (f); (iii) the phase of the sinusoidal stimulus (phi(tot)); (iv) the maximal amplitude of the distorted microphonic signal (Vsat); (v) the sensitivity of the transduction process (Z); and (vi) the operating point on the sigmoidal transfer curve (Eo). The software obtains the least-squares fit to the CM waveforms by continuously deriving the six parameters at a speed of about one determination per second. The independent fitting of the frequency and phase allows the data to be analysed off-line from data previously recorded to tape (i.e. the frequency and phase of the microphonic response need not be known accurately beforehand). We present here an outline of the software we have used, and give an example of the changes which can be monitored using the technique (transient asphyxia). The method's advantages and limitations have been discussed in our previous paper. The virtual instrument described here is available from the authors on request.
Related Concept Videos
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to the...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
UV–Vis Spectroscopy: Molecular Electronic Transitions
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...