Related Experiment Video
Updated: Sep 25, 2026

Profiling of Methyltransferases and Other S-adenosyl-L-homocysteine-binding Proteins by Capture Compound Mass Spectrometry (CCMS)
Published on: December 21, 2010
High-mass-measurement accuracy and 100% sequence coverage of enzymatically digested bovine serum albumin from an
J E Bruce1, G A Anderson, J Wen
1Environmental and Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, USA.
Abstract:
The application of Fourier transform ion cyclotron resonance (FTICR) mass spectrometry to the analysis of polypeptide mixtures resulting from proteolytic digestion is described. A new 11.5-T FTICR mass spectrometer has been applied for the analysis of tryptic digestion mixtures of the protein bovine serum albumin (BSA). The improved cyclotron frequency stability and reduced frequency shifts observed over a wide range of trapped ion population sizes provide the ability to signal average spectra without degrading mass measurement accuracy, requiring internal calibration or advanced data processing schemes to compensate for variations in ion cyclotron signals brought about by different population sizes. A total of 100 spectra were signal-averaged leading to the observation of a total of 123 isotope distributions with a signal-to-noise ratio greater than 3:1. From those distributions, 86 can be ascribed to tryptic fragments of BSA on the basis of mass measurement errors of 10 ppm or less. Of these, 71 were within 2 ppm error limits corresponding to complete amino acid sequence coverage and an average error of 0.77 ppm. These results indicate that high-accuracy measurements are feasible for a large number of species detected simultaneously without the necessity for internal calibration and indicate the potential of such measurements, when combined with chromatographic separations, for facilitating more rapid identification of large numbers of proteins.
More Related Videos
07:49Matrix-assisted Laser Desorption/Ionization Time of Flight (MALDI-TOF) Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
10:05Large-scale Top-down Proteomics Using Capillary Zone Electrophoresis Tandem Mass Spectrometry
Published on: October 24, 2018
Related Concept Videos
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...