Related Experiment Video
Updated: Aug 3, 2026

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Detection of Björk-Shiley convexo-concave heart valve outlet strut single leg separations: consensus image
K D Hopper1, I C Gilchrist, J R Landis
1Department of Radiology, Department of Medicine, Penn State University, Hershey, Penn. 17033, USA.
Background:
Conventional cineradiology has been used clinically to detect partially broken outlet struts (single leg separations, SLSs) in normally functioning Björk-Shiley convexo-concave (C/C) heart valves. The value of radiographic screening has, however, been debated in the medical literature. This study uses the same radiographic technique in sheep implanted with known-status C/C valves in combination with a newly developed geometric image magnification radiography system. This study was designed to test whether sensitivity and specificity of radiographic screening of C/C valves in detecting SLSs could be improved through the combination of readers and imaging modalities.
Methods:
Twenty-one sheep with mitral C/C valves were studied on both systems. Five were used for extensive scanning training. When operators were expert on both systems, 16 blinded study valves (4 intact and 12 with outlet strut SLSs) were scanned twice on both systems, first on a modified conventional and then a prototype geometric image magnification (Feinfocus(TM)) cineradiographic system by two expert physicians working together.
Results:
Among the 32 scanned valves, the two combined expert physicians were required to evaluate 40 intact legs and 24 with an SLS. For all SLS valves, the conventional and Feinfocus systems separately detected 50 (12/24) and 54% (13/24), respectively. When the two systems were combined, the final consensus score was correct in 67% (16/24) of all SLS valves.
Conclusions:
Combined modality, paired expert physicians detected 67% of all SLSs. The Feinfocus system might be best reserved for those patients in whom the Siemens screening study demonstrates in minimally suspicious (grade 2) or suspicious (grade 3) appearance of a C/C valve outlet strut leg.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

