Microbiological and radioactive contamination from radioaerosol ventilation scanning: is there a problem?
Related Experiment Video
Updated: Oct 19, 2026

Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
A Brown1, N J Carter, M J O'Doherty
1Department of Nuclear Medicine, Kent and Canterbury Hospital, UK.
Abstract:
Radioaerosol lung imaging may result in (a) microbiological contamination of nebulizer circuits (a potential hazard to patients if the circuit is re-used), and (b) radioaerosol contamination of the atmosphere (a hazard to staff, particularly if inhaled, ingested or both). Altogether, 138 circuits were assessed for bacteriological contamination, 93 of which had been used for ventilation perfusion studies and 45 for lung permeability studies in human immunodeficiency virus (HIV) positive patients. The circuits used for ventilation/perfusion (V/Q) studies were re-used over a period of 1-5 days. The mouthpiece and Y-piece were changed between patients. The circuits used for permeability studies were changed in toto for each patient. Organisms belonging to normal respiratory flora were isolated from the Y-piece, mouthpiece or both in 9 of 138 cases. An additional case (from one of the HIV-positive patients) demonstrated a growth of methicillin-resistant Staphylococcus. We also demonstrated bacteriological growth, most likely of patient origin, in circuit tubing in 11 cases at the end of the first day's use and 9 cases by day 5. None of the circuits used for HIV-positive cases were culture-positive. Airborne radioactive contamination was assessed during radioaerosol inhalation with and without an air extractor device (Nederman) during 40 ventilation studies. The 20 studies with air extraction showed a large decrease in room air contamination. Nebulizer circuits can, and occasionally do, become contaminated with patients' organisms; this represents a potential infection control hazard and therefore re-use is contraindicated. The use of an air extractor will significantly reduce airborne radioaerosol contamination.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Biological Effects of Radiation
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Radiological Investigation I: X-ray and CT
Physical Methods for Controlling Microbial Growth: Radiation and Filtration