Cardiac memory after radiofrequency ablation of accessory pathways: the post-ablation T wave does not forget the
B Herweg1, J D Fisher, A Ilercil
1Department of Medicine, Cardiology Division, Arrhythmia Service, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10467-2490, USA.
Introduction:
Normalization of the pre-excited QRS following ablation is accompanied by repolarization changes but their directional relationship to changes in ventricular activation has not been well characterized.
Methods:
Accordingly, we measured QRS and T wave vectors and QRS-T angles from 12 lead ECG recordings immediately before and after accessory pathway (AP) radiofrequency ablation in 100 consecutive patients. Patients with bundle branch block, intraventricular conduction defect or intermittent pre-excitation were excluded, leaving a study group of 45 patients: 35 with pre-excitation and 10 with concealed APs.
Results:
With AP ablation, changes occurred in the QRS and T wave vectors and QRS-T angles that were essentially equal and opposite, so that the newly normalized QRS complex and QRS vector were accompanied by a T wave whose vector approximated that of the pre-ablation QRS vector. This tended to maintain a large QRS-T angle: 72 degrees +/- 50 degrees before, and 54 degrees +/- 34 degrees after QRS normalization (p = NS). A QRS-T angle >40 degrees was found before and after ablation in 22/35 patients (63%) with baseline pre-excitation; but never in patients with a concealed AP (p = 0.001). The angle between the pre-excited QRS and the post-ablation T wave was 35 degrees +/- 37 degrees, and =40 degrees in 25/35 patients (71%). The change in T wave axis with QRS normalization correlated in magnitude with the QRS-T angle before ablation (r = 0.73, p < 0.0001). The change in QRS axis correlated with the QRS-T angle after ablation (r = 0.37, p < 0.03). Shorter AP effective refractory periods (ERPs) correlated with wider QRS-T angles after ablation (r = -0.39, p < 0.03). The ECG leads manifesting these changes depend on AP location.
Conclusion:
T-wave changes after ablation of APs (1) are dependent on anterograde AP conduction at baseline and are not observed with concealed APs; (2) correlate in magnitude directly with the change in QRS axis and inversely with the anterograde AP-ERP; (3) are related to AP location. With termination of pre-excitation secondary repolarization changes immediately disappear and the post ablation T wave axis approximates that of the pre-excited QRS. Recognition of this sequence may prevent unnecessary clinical interventions.
More Related Videos
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrophysiology of Normal Cardiac Rhythm
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Mechanism of Cardiac Arrhythmias
Cardiopulmonary Resuscitation III: AED Use
Dysrhythmias IV: Characteristics of Bradyarrhythmias