Criteria for evaluating the condition of a tropical cyclone warning system

D Parker1

  • 1Flood Hazard Research Centre, Middlesex University. D.Parker@mdx.ac.uk

Disasters
|October 6, 1999
PubMed

Related Concept Videos

What is Weather?01:07

What is Weather?

Overview
Transient and Steady-state Response01:24

Transient and Steady-state Response

In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state response.
Routh-Hurwitz Criterion I01:15

Routh-Hurwitz Criterion I

Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Reclosers and Fuses01:26

Reclosers and Fuses

Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
Zones of Protection01:16

Zones of Protection

In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Design Example: Calculating Safe Diameter for Wind-Exposed Disc01:17

Design Example: Calculating Safe Diameter for Wind-Exposed Disc

Assessing safety in wind-exposed installations is crucial to preventing potential failures. This example explores the calculation and design adjustments needed to mount a circular disc on a building facade, where wind forces are a primary concern. A 4-meter diameter disc was initially designed as an aesthetic feature facing winds at a velocity of 25 meters per second, with an air density of 1.25 kilograms per cubic meter. Given these conditions, the drag force on the disc was determined using...