Related Experiment Video
Updated: Aug 12, 2026

Creating Dynamic Images of Short-lived Dopamine Fluctuations with lp-ntPET: Dopamine Movies of Cigarette Smoking
Published on: August 6, 2013
A comparison of 11C-labeled L-DOPA and L-fluorodopa as positron emission tomography tracers for the presynaptic
R Torstenson1, J Tedroff, P Hartvig
1The Subfemtomole Biorecognition Project, Uppsala University and Japanese Research and Development Council, Sweden.
Abstract:
11C-labeled 3,4-Dihydroxy-phenyl-L-alanine (L-DOPA) and L-fluorodopa were used as tracers for the functional state of the presynaptic dopamine system in anesthetized monkeys with positron emission tomography. The radiotracer disposition in brain tissue and plasma were studied and effects induced by pharmacologic challenges were evaluated. 6R-L-erythro-5,6,7,8-tetrahydrobiopterin (6R-BH4) increased the striatal influx rate constant, e.g., striatal K(i) for L-[beta-11C]DOPA, but it induced no effect on the K(i)-value using L-[beta-11C]-6-fluorodopa. Studies of radiolabeled tracer and metabolites in plasma showed substantial differences between the two tracers. At baseline conditions, 60% unchanged L-[beta-11C]DOPA was detected in plasma 50 minutes after tracer injection and the 3-O-methylated fraction accounted for 25% of total radioactivity. For L-[beta-11C]-6-fluorodopa, the relation was inverse; about 25% unchanged tracer and 60% 3-O-methyl metabolite were present in plasma after 50 minutes. A site-specific 11C-labeling in the carboxylic position in the molecules revealed a significant specific retention of radioactivity in striatum with L-[car-boxy-11C]-6-fluorodopa but not with L-[carboxy-11C]DOPA. The 3-O-methyl metabolite of L-DOPA is known to pass the blood-brain barrier and may interfere with the calculation of the K(i)value using a brain reference region. Thus, extensive 3-O-methylation in circulation of the fluorinated analog could obscure the detectability of potential functional change in striatal K(i) of the tracer when using a reference tissue model for calculation.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

![Radiosynthesis of 1-(2-[18F]Fluoroethyl)-L-Tryptophan using a One-pot, Two-step Protocol](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F63025.jpg&w=3840&q=50)