Residual blood in neonatal oxygenators after drainage
B Henrick1, P Keartland, A McCarthy
1Mater Misericordiae Hospital, Department of Cardiothoracic Surgery, Dublin, Ireland.
Abstract:
The objective of this investigation was to measure the quantity of residual blood remaining in neonatal cardiopulmonary bypass (CPB) circuits after they had been drained and to assess the overall significance with regards to total patient blood volume. The residual blood volume left in three infant/neonatal CPB circuits-Medtronic Minimax 3381 (Group MM; n = 5), Polystan Safe Micro (Group SM; n = 6), and Terumo Capiox 308 (Group CX; n = 3)--after they had been drained was determined. This was done by using an electronic scale to weigh the circuit before setup and after CPB when all possible blood was recovered from it. Total priming volume, estimated patient blood volume, residual blood volume, surgical blood loss in theater, and autogeneic blood usage were recorded in each case. Mean residual blood volumes measured were MM = 161 ml (SD 27 ml), SM = 103 ml (SD 19 ml), and CX = 133 ml (SD 15 ml). These volumes were significant, because calculations show that the volume of red cells lost in the circuit is equivalent to fourteen percent of the total patient blood volume. In view of this, neonatal oxygenator design should be minimized to reduce the priming volume and more consideration should be given to ease of residual blood recovery.
More Related Videos
09:54Lung Rapid Recovery Procurement Combined with Abdominal Normothermic Regional Perfusion in Controlled Donation after Circulatory Death
Published on: August 15, 2022
08:58Development of a Neonatal Piglet Acute Lung Injury Model Recreating the Early Environment of Preterm Infant Lungs
Published on: October 31, 2025
Related Concept Videos
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...