The effect of magnitude and frequency of interfragmentary strain on the tissue response to distraction osteogenesis
Related Experiment Video
Updated: Aug 13, 2026

Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
U Meyer1, T Meyer, H P Wiesmann
1Department of Maxillofacial Surgery, University of Münster, Germany.
Purpose:
Bone regeneration is believed to be partially controlled by the applied local mechanical strain. To test whether the magnitude or frequency of discontinuous traction regulates the tissue response, defined daily strains were applied on mandibular osteotomies using an implanted mechanical distractor.
Materials And Methods:
Unilateral mandibular osteotomies were performed in skeletally immature rabbits (n = 36). and distraction was done by applying 2,000, 20,000, 200,000, or 300,000 microstrains once or 10 times (2,000, 20,000 microstrains) per day, respectively. Sham-operated animals (n = 6), serving as controls, underwent frame application and osteotomy without distraction. At the end of the distraction process, the newly formed tissue was evaluated histomorphometrically by the use of a well-defined scoring system of bone-forming indices.
Results:
The highest bone-forming indices were detected in the osteotomized, nondistracted group and in samples exposed to a physiologic strain (2,000 microstrains). Application of hyperphysiologic strains (200,000 and 300,000 microstrains) resulted in the formation of fibrous tissue and decreased bone-forming indices. Using Kruskal-Wallis tests, a statistically significant relationship was found between the bone-forming indices and the applied strain magnitudes. Scanning and transmission electron microscopic examinations showed osteoblastic differentiation and early mineral deposition in samples distracted up to 20,000 microstrains, whereas higher strain magnitudes led to the formation of fibroblast-like cells surrounded by collagen fibrils and only slight mineralization. Multiple strain applications (10 cycles/d vs 1 cycle/d) did not alter the histomorphometric indices or ultrastructural morphology significantly but increased the amount of newly formed tissue.
Conclusions:
These results suggest that the magnitude and not the frequency of mechanical loading controls the differentiation of bone cells and the subsequent formation of bone tissue.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity