An approach to an objective background subtraction for elemental mapping with core-edges down to 50 eV: description,
A Haking1, H Troester, K Richter
1German Cancer Research Center (DKFZ), Biomedical Structure Analysis Group, Heidelberg, Germany.
Abstract:
To image the distribution of a specific element in a specimen with an energy filtering TEM, the element-unspecific background under the core-edge has to be subtracted. The most commonly used procedure is the three-window power-law method leading to considerable systematic errors for low-energy core-edges. Here a new method is described which can be considered as a generalized difference method. Characteristic examples for element detection in biological specimens using this method are shown. The background under the core-edge can be described by one or two pre-edge windows as a polynome of third order. This function can be deduced from specimen areas that are not known to contain the element or from a second specimen used as a standard. Control experiments showed that background subtraction for on-overlapping core-edges in the low-loss region (50-200 eV) needs two pre-edge images, whereas at higher-energy losses (> 300 eV) only one pre-edge image is necessary. With the method described, objective elemental mapping becomes possible even for edges at 50-100 eV. This was proven for the M2,3-edge of iron at 60 eV. The detection of phosphorous was possible with a signal-to-noise ratio five times higher than when using the three-window method. Preliminary data showed that it should be possible to detect calcium with only one image before the edge.
More Related Videos
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Extraction: Advanced Methods
Introduction and Methods of Leveling