Monte Carlo-based correction of scattering effects in low-energy mass attenuation experimental measurements of
João Pedro Carvalho Andrade1, William Luna Salgado2, César Marques Salgado2
1Instituto de Engenharia Nuclear (IEN), Serviço de Desenvolvimento de Técnicas Nucleares (SEDTN), Rio de Janeiro, RJ, Brazil; Universidade Federal do Rio de Janeiro (UFRJ), Escola Politécnica (POLI), Rio de Janeiro, RJ, Brazil.
Abstract:
Low-energy gamma-ray attenuation measurements are strongly influenced by coherent (Rayleigh) scattering and geometrical effects, particularly under non-ideal broad-beam experimental conditions. In this work, a Monte Carlo-based correction methodology using the MCNP6 code was developed to improve the accuracy of mass attenuation coefficient measurements in 3D-printed polymeric materials. Experimental measurements were performed for acrylonitrile butadiene styrene (ABS), polyethylene terephthalate glycol (PETG), and polylactic acid (PLA) using 241Am and 137Cs gamma-ray sources in combination with a 2 × 2″ NaI(Tl) scintillation detector. Monte Carlo simulations were conducted to reproduce both the experimental measurement geometry and an idealized narrow-beam configuration, enabling the determination of correction factors for low-energy attenuation measurements affected by scattering effects. Additional simulations were performed within the 40-100 keV energy range to develop mathematical fitting functions capable of estimating scattering and geometrical corrections as a function of photon energy. Aluminum samples were also analyzed as a reference material to validate both the experimental methodology and the MCNP6 simulations. The obtained attenuation coefficients were compared with NIST XCOM reference data, showing maximum deviations of 4.94% for the 137Cs measurements (aluminum) and 9.50% for the corrected 241Am measurements (PLA). Results demonstrated that the proposed correction methodology significantly improved agreement between experimental and reference attenuation coefficients, particularly for low-energy photons strongly affected by Rayleigh scattering and geometrical effects. The proposed approach enables reliable attenuation measurements to be performed even under non-ideal experimental conditions, particularly in laboratories without access to highly collimated measurement systems or high-intensity radioactive sources. This methodology contributes to the assessment of 3D-printed polymers as alternative materials for radiation shielding and nuclear technology applications.