Measurement of the Pressure-volume Curve in Mouse Lungs
Published on: January 27, 2015
Effect of pulmonary edema on tracheal diameter
J R Snapper1, D S Trochtenberg, Y S Hwang
1The Center for Lung Research, Vanderbilt University School of Medicine, Nashville, TN 37232, USA.
Background:
Though it is well known that cardiogenic and noncardiogenic pulmonary edema can cause changes in lung mechanics, actual alterations in tracheal diameter have not been described.
Objective:
To evaluate the effects of pulmonary edema induced by increased left atrial pressure (cardiogenic) and Perilla ketone (PK; noncardiogenic) on tracheal diameter in chronically instrumented awake sheep.
Methods:
We investigated the effects of two mechanistically distinct types of pulmonary edema on tracheal diameter in chronically instrumented awake sheep. Cardiogenic pulmonary edema (analogous to congestive heart failure in humans) was induced by increasing left atrial pressure ( upward arrowP(LA)) by inflating the balloon on a Foley catheter positioned in the mitral valve annulus to cause partial obstruction to flow across the valve (n = 18). Noncardiogenic pulmonary edema (increased pulmonary microvascular permeability pulmonary edema analogous to the acute respiratory distress syndrome in humans) was produced by the intravenous administration of PK (n = 11). Lateral chest radiographs (CXRs) were scored by a standardized 5-point scoring system for the severity of pulmonary edema, and tracheal diameter was measured at a fixed location in the carina. Three radiologists, blinded to sheep identification number and experimental protocol, evaluated the radiographs independently at different points in time for edema severity and tracheal diameter. The sheep were sacrificed immediately after the final CXR, and wet/dry lung weight ratio (W/D ratio) was determined.
Results:
Both upward arrowP(LA) and PK were associated with statistically significant tracheal narrowing ( upward arrowP(LA): 20.3 +/- 0.6 to 15.1 +/- 0.9 mm; PK: 20.2 +/- 0.6 to 14.1 +/- 1.4 mm). Tracheal narrowing correlated with the severity of the pulmonary edema determined radiographically ( upward arrowP(LA): r = -0.69, p < 0.01; PK: r = -0.62, p < 0.01) and by W/D ratio ( upward arrowP(LA): r = -0.64, p < 0.05; PK: r = -0.54, p < 0. 05).
Conclusions:
We conclude that tracheal narrowing occurs in sheep models of both cardiogenic and noncardiogenic pulmonary edema and that the degree of narrowing correlates with the severity of the edema.
Related Concept Videos
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of the...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Atelectasis II: Pathophysiology
Chronic Obstructive Pulmonary Disease II: Emphysema
Pulmonary Edema II: Pathophysiology