Related Experiment Video
Updated: Aug 10, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
The dual-isotope ProstaScint imaging procedure: clinical experience and staging results in 145 patients
1Department of Radiology, College of Medicine, University of Illinois, Chicago, USA.
Purpose:
Whole-body, regional planar, and SPECT imaging using the In-111-labeled monoclonal antibody capromab pendetide (In-111 MAb; ProstaScint) has been shown to increase the detection of early disease spread in patients with prostate cancer. However, recognition of metastatic tumor sites can be difficult, especially if the involved nodes are near blood vessels. We have developed an alternate approach to the identification of metastatic sites that is based on a single simultaneous In-111 MAb and Tc-99m RBC SPECT acquisition of the pelvis and abdomen on day 5 after injection. We have also developed software that dynamically subtracts the Tc-99m RBC data set (vascular component) from the In-111 MAb data set (prostate and lymph node component), which allows for easier identification of metastatic sites.
Methods:
We evaluated the effectiveness of ProstaScint for staging 145 patients with prostate cancer, 19 newly diagnosed and 126 with recurrence, using these two modifications.
Results:
With clinical follow-up in 13 of 19 (68%) patients with primary disease, 10 of 13 (78%) had organ-confined disease. With follow-up in 64 of 126 (51%) patients with possible recurrent disease, 49 of 64 (77%) were found to have prostatic fossa activity only. Disease stage was deemed more advanced in 3 of 13 (22%) patients with primary cancer and in 13 of 64 (20%) of those with recurrent disease based on ProstaScint findings when all other imaging tests were inconclusive. Six patients with recurrent disease had negative results of their scans. In the 16 patients with more advanced disease, 3 of 59 lesions (5%) were documented as false positive, and there were no reported cases of false-negative findings.
Conclusions:
Using both the dual-isotope procedure and the subtraction analysis software with the ProstaScint examination provides additional information for staging primary and possibly recurrent prostate cancer compared with standard imaging techniques.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

