Related Experiment Videos
[Intestinal anastomosis in urology. Comparison of techniques]
M Diana1, M Schettini, M Gallucci
1Divisione di Urologia, Ospedale Cristo Re, Roma.
Background:
Three different intestinal anastomosis were compared during reconstructive urologic surgery; time, cost and incidence of complications were evaluated.
Methods:
From November 1993 to February 1997, 45 patients (43 males and 2 females) were submitted to ileal resection to fashion 30 ileal neobladder, 8 ileal conduits and 7 augmentation ileocystoplasties. The patients were randomized in 3 groups. In the first group the intestinal continuity was performed by BAR; the second one was treated by GIA stapling device; the last underwent a manual suture with interrupted stitches double layer (vicryl).
Results:
The mean follow-up was 18 months. The mean time of canalization was 6.3 days. The complications were: one intestinal subocclusion (group 1); one abdominal wound infection (group 2); one anastomotic leak and one pulmonary embolism (group 3). The mean time of anastomosis was 18, 12 and 39 minutes respectively. The average total cost was 915,000 lire in group 1; 1,280,000 lire in group 2; 632,000 lire in group 3.
Conclusions:
The conclusion is drawn that mechanical devices (BAR and stapler) are more convenient and advisable in reconstructive urologic surgery, for their quickness, effectiveness and final total cost.