Measurements of systolic time intervals using a transoesophageal pulsed echo-Doppler
J P Tournadre1, R Muchada, S Lansiaux
1Service d'Anesthésie-Réanimation, Hôpital de l'Hôtel-Dieu, Lyon, France.
Abstract:
Measurement of systolic time intervals (STI), an index of left ventricular (LV) systolic function, is usually labour intensive and requires considerable expertise to perform accurately. We have evaluated the accuracy of an automated, continuous and non-invasive STI measurement technique using a descending aortic blood velocity Doppler signal obtained using a transoesophageal echo-Doppler system (TEDS) and an ECG signal. STI were measured in adult pigs using a transoesophageal probe (4 x 4 mm pulsed wave Doppler transducer, 5-MHz frequency and a 3 x 3 mm echo transducer, 10-MHz frequency) associated with an ECG recorder. Measurements were performed at baseline and after injection of esmolol and dobutamine. TEDS data were compared with those obtained by one-line recordings of the electrocardiogram and the central aortic arterial pressure wave. Similar mean values were observed for pre-ejection period (PEPI), LV ejection time (LVET) and PEP/LVET with the two methods. Agreement between the methods (Bland and Altman's test) was excellent with 95% confidence intervals for PEP, LVET and PEP/LVET of -7.17 to +1.37 ms, -12.64 to +0.24 ms and -0.033 to +0.028, respectively. We conclude that the combination of descending aorta blood velocity Doppler and ECG signal is an alternative technique for non-invasive and objective measurement of STI, allowing continuous monitoring of LV systolic function.
More Related Videos
Related Concept Videos
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical indicator...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...