Abstract:
Peptide mapping by capillary electrophoresis (CE) with UV detection is problematic for the characterization of proteins that can only be obtained at low micromolar concentrations. Dilution of peptide fragments during digestion of the protein can further reduce the detection sensitivity in peptide mapping to the point where analysis at sub-micromolar concentrations is not possible. A remedy to this problem is preconcentration (sample enrichment) of the proteolytic digest by solid-phase extraction (SPE). To minimize non-specific adsorptive losses during sample handling, on-line SPE-CE is preferred. However, packed-inlet SPE-CE is not always feasible due to either instrument or sample limitations. We describe here a simple method of preconcentration by discontinuous on-line SPE-CE, specifically applied to peptide mapping in low-pH separation buffer after protein digestion in a solid-phase enzyme microreactor. The SPE-CE system does not require application of a low pressure during electrophoretic separation to overcome reversed electroosmotic flow because the preconcentrator device is disconnected from the separation capillary before the electric field is applied. Up to a 500-fold preconcentration factor can be achieved with this device, which can be reused for many samples. Parameters such as the volume of desorption solution, the adsorption/desorption (chromatographic) process, reproducibility of packing the SPE preconcentrator and effects of sample concentration on the peptide map are investigated.
More Related Videos
10:05Large-scale Top-down Proteomics Using Capillary Zone Electrophoresis Tandem Mass Spectrometry
Published on: October 24, 2018
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...