Related Experiment Video
Updated: Oct 17, 2026

Isolation of Neonatal Extrahepatic Cholangiocytes
Published on: June 5, 2014
[Perinatal monitoring in intrahepatic cholestasis of pregnancy]
The sensitivity of meconium stain in amniotic fluid for prediction of fetal well-being in intrahepatic cholestasis of pregnancy(ICP) was evaluated. The study consisted of an ICP group(n = 30), and a control group (n = 30) and the umbilical arterial pH value(< 7.2) was used as a standard. The positive and negative predicttive valus of meconium-stained amniotic fluid in ICP group were 80.0%; the positive and negative predictive values in control group were 60.0% and 92.0% respectively. There was no significant difference (P > 0.05) between the two groups in positive and negative predictive values. However, the positive and negative predictive values of the two groups were high, which indicated that meconium-stained amniotic fluid related to fetal hypoxia. Moreover, the incidence of meconium-stained amniotic fluid in ICP was higher than that in control (40.0%: 16.70%, P < 0.05). Therefore, we suggest that the amniotic fluid of patients with ICP should be observed very closely. When meconium-stained amniotic fluid is discovered, delivery by cesarean section is imminent.
The sensitivity of meconium stain in amniotic fluid for prediction of fetal well-being in intrahepatic cholestasis of pregnancy(ICP) was evaluated. The study consisted of an ICP group(n = 30), and a control group (n = 30) and the umbilical arterial pH value(< 7.2) was used as a standard. The positive and negative predicttive valus of meconium-stained amniotic fluid in ICP group were 80.0%; the positive and negative predictive values in control group were 60.0% and 92.0% respectively. There was no significant difference (P > 0.05) between the two groups in positive and negative predictive values. However, the positive and negative predictive values of the two groups were high, which indicated that meconium-stained amniotic fluid related to fetal hypoxia. Moreover, the incidence of meconium-stained amniotic fluid in ICP was higher than that in control (40.0%: 16.70%, P < 0.05). Therefore, we suggest that the amniotic fluid of patients with ICP should be observed very closely. When meconium-stained amniotic fluid is discovered, delivery by cesarean section is imminent.
Related Concept Videos
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol abuse, or...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
