Pressure ulcer development due to unrelieved pressure during extended cardiovascular, orthopedic, and other procedures is an important clinical problem. Because blood flow changes within pressure-loaded tissue affect the skin breakdown process, the relative effects of 2 support surface strategies on trochanter skin blood flow were investigated.
Design:
Skin blood perfusion was assessed by laser Doppler methods during 1 hour of continuous loading. Blood perfusion was measured before and during hip-down loading on a gel pad (static surface) and a dynamic multisegmental surface that provided periodic alternating pressure relief. Female volunteers (N = 20, age > or = 60 years) were tested on each surface in random order with sequential tests separated by 5 to 8 days. Effects were assessed by comparing perfusion during the first and last 15 minutes of hip-down loading with a 15-minute baseline.
Setting:
Research center.
Results:
Pre-load perfusions (dynamic vs static support) were similar (0.57 +/- 0.06 vs 0.64 +/- 0.08). During loading, however, a significant progressive increase in perfusion was noted only with dynamic support; by the end of the loading interval, this increase in perfusion had significantly exceeded the pre-load baseline (1.22 +/- 0.26, P = 0.001).
Conclusion:
These findings reveal a surface-dependent blood flow impact, with the multisegmental dynamic approach being associated with greater flow during loading. The mechanism, though speculative, is consistent with a greater vascular adaptation potential offered by the dynamic surface. Conditions that facilitate such adaptive flow increases would appear to be of considerable benefit in helping to prevent ulcer development.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease IV: Nursing Management