Detection of coronary artery disease using maximum value of ST/HR hysteresis over different number of leads
J Viik1, R Lehtinen, J Malmivuo
1Ragnar Granit Institute, Tampere University of Technology, Finland.
Insights
Optimizing exercise electrocardiogram (ECG) lead selection improves coronary artery disease (CAD) detection using ST/heart rate (HR) hysteresis. Careful lead selection enhances diagnostic accuracy, with specific leads like V5 showing higher utility.
Area of Science:
- Cardiology
- Medical Diagnostics
- Exercise Physiology
Background:
- Coronary artery disease (CAD) diagnosis relies on exercise electrocardiography (ECG).
- ST segment depression/heart rate (ST/HR) hysteresis is a parameter used in ECG analysis for CAD detection.
- Optimizing the number and configuration of ECG leads can potentially improve diagnostic accuracy.
Purpose of the Study:
- To evaluate the impact of the number and ordering of exercise ECG leads on the diagnostic performance of ST/HR hysteresis for CAD detection.
- To identify optimal lead combinations for maximizing the diagnostic capacity of ST/HR hysteresis.
Main Methods:
- Studied exercise ECGs from 127 CAD patients and 220 controls using a Mason-Likar 12-lead system.
- Systematically varied the number of leads (from 2 to 12) and their order, prioritizing leads that maximized the area under the receiver operating characteristic (ROC) curve.
- Assessed diagnostic importance using ROC analysis, a fixed 0.01 mV partition criterion, and a fixed 80% specificity.
Main Results:
- Lead V5 demonstrated the highest individual diagnostic capacity, while leads aVL and V1 showed the least.
- The diagnostic capacity of ST/HR hysteresis improved significantly with the inclusion of up to 8 leads, after which performance decreased.
- A maximum search procedure identified lead combinations that enhanced diagnostic power.
Conclusions:
- Increasing the number of leads can improve the diagnostic capacity of ST/HR hysteresis for CAD detection.
- The specific selection and ordering of leads are crucial for maximizing the effectiveness of ST/HR hysteresis in CAD diagnosis.
- Optimal lead sets, rather than all 12 leads, may provide the best diagnostic yield.
Abstract:
We have studied the effect of the number and ordering of exercise electrocardiographic (ECG) leads when using the maximum value of the ST segment depression/heart rate (ST/HR) hysteresis over a different number of leads for the detection of coronary artery disease (CAD). The study population consisted of 127 patients with CAD and 220 patients with a low likelihood of the disease referred for an exercise test at Tampere University Hospital, Finland. The lead system used was the Mason-Likar modification of the standard 12-lead system, and exercise tests were performed on a bicycle ergometer. The number of leads was studied using lead sets consisting of first 2 leads, then 3 leads, and so on, up to all 12 leads. The criterion for the order of inclusion of the next lead in the new lead set was based on the maximized area under the receiver operating characteristic (ROC) curve for the new lead set. The importance of the number of leads was evaluated by means of three different approaches: ROC analysis; using a fixed partition criterion of 0.01 mV; and using a fixed specificity value of 80%. According to the results, the most powerful diagnostic capacity of an individual lead was in lead V5, and the most deficient diagnostic capacities were in leads aVL and V1. Using the maximum search procedure, it was possible to improve the diagnostic capacity of the ST/HR hysteresis by anything from 4 up to a maximum of 8 leads. After that it started to decrease rapidly. In conclusion, this study suggests that the diagnostic capacity of the ST/HR hysteresis could be improved by increasing the number of leads. However, the selection of leads is of major importance when using the maximum value of the ST/HR hysteresis over the leads in the detection of CAD.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Holter Monitor: 24-Hour Monitoring