A new sensor for monitoring chest wall motion during high-frequency oscillatory ventilation
C Davis1, A Mazzolini, J Mills
1Centre for Imaging and Applied Optics, School of Biophysical Sciences and Electrical Engineering, Swinburne University of Technology, Melbourne, Australia. claired@swin.edu.au
Abstract:
The recently developed technique of fibre optic respiratory plethysmography (FORP) has been modified to monitor the rapid, small amplitude movements of the chest wall during high-frequency oscillatory ventilation (HFOV). The FORP sensor is an expandable belt encircling the chest, in which is housed a fibre optic loop that alters its radius of curvature as a function of chest perimeter. These curvature changes cause variations in macrobending losses of light transmitted through the fibre, which are proportional to the chest perimeter. Dynamic measurement of transmitted light intensity can hence be used to monitor chest wall motion (CWM). For application to HFOV, the design of the FORP belt was altered to increase sensitivity and the materials were chosen to maximise macrobending effects induced by the CWM. FORP was tested in four piglets ventilated with HFOV, both in the normal and surfactant-deficient lung. Measurement of CWM was possible over the full range of tidal volumes and ventilation frequencies used during HFOV. In all cases, the measured frequency of the CWM fell within 3% of the applied ventilation frequency. In addition, the technique was sufficiently sensitive to detect changes in the amplitude of CWM in response to changes in applied tidal volume. It is anticipated that application of this new non-invasive measurement device will lead to an increased understanding of the dynamics of chest and abdominal wall motion during HFOV.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...