Related Experiment Video
Updated: Jul 13, 2026

Epithelial Cell Repopulation and Preparation of Rodent Extracellular Matrix Scaffolds for Renal Tissue Development
Published on: August 10, 2015
Normalization of clearances in peritoneal dialysis using a formula for body water derived from an end-stage renal
A H Tzamaloukas1, G H Murata, D Malhotra
1New Mexico Veterans Affairs Health System, University of New Mexico School of Medicine, Albuquerque 87108, USA.
Objective:
To compare body water (V) estimates from the Chertow formula (Vc), which was derived in an end-stage renal disease population, to V estimates from the Watson formulas (Vw) in continuous ambulatory peritoneal dialysis (CAPD) patients. To identify CAPD patients in whom Vc is preferred to Vw for clearance studies.
Design:
Retrospective analysis of clearance studies.
Setting:
Dialysis units of four academic medical centers.
Participants:
302 subjects on CAPD.
Intervention:
613 clearance studies by standard methods.
Main Outcome Measures:
Comparisons between Vc and Vw, and between urea clearance normalized by Vc [(KtVc)ur] and Vw [(Kt/Vw)ur].
Results:
Vc exceeded Vw by 3.5 +/- 1.6 L (p < 0.001), or 9.6% on average. This degree of overestimation of Vw is in the range of body water estimates found in CAPD subjects with severe volume overload (> 5% of body weight) in previous studies. Total (Kt/Nw)ur exceeded total (Kt/Vc)ur by 8.6%. By linear regression, Vc = -0.589 + (1.112 x Vw), r = 0.983. Vw exceeded Vc in only 12 studies. Young age, short height, low body weight, and low prevalence of diabetes characterized the studies with Vw > Vc. Total (Kt/Vw)ur was adequate (> or = 2.0 weekly) in 276 studies. Among these, 74 studies had inadequate total (Kt/Vc)ur (< 2.0 weekly). By logistic regression, the predictors of inadequate (Kt/Vc)ur, when (Kt/Vw)ur was adequate, included the presence of diabetes, great height, and long duration of CAPD.
Conclusions:
Vc provides estimates of body water exceeding those provided by Vw in a great majority of CAPD patients. Consequently, approximately 25% of the clearance studies that are adequate when Vw is used as the normalizing parameter may be inadequate when Vc is used. Vc may provide a more appropriate estimate of body water than Vw in CAPD patients with volume overload.
Related Concept Videos
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Peritoneal Dialysis I: Introduction and Procedure
Peritoneal Dialysis III: Nursing Management
Hemodialysis III: Nursing Management

