Related Experiment Videos
[Superparamagnetic iron oxide enhanced MR angiography of the portal vein system]
S A Schmitz1, T Albrecht, K Jensen
1Radiologische Klinik, Klinikum B. Franklin, FU Berlin. s.schmitz@medizin.fu-berlin.de
Purpose:
Superparamagnetic iron oxide (SPIO) is used for the detection of focal liver lesions. The current study examines whether the blood-pool effect of an approved substance is adequate for contrast-enhanced MR angiography of the portal venous system.
Methods And Materials:
Fifteen patients [9 women, 6 men, mean age 57 (34-73)] were examined with a breathhold 3D-FISP sequence (TR/TE/FA; 5 ms/2 ms/25 degrees) at 1.5 Tesla (Vision; Siemens, Erlangen) during the last third of a half-hour Infusion of a standard dose (15 mumol Fe/kg) of AMI-25 (Endorem, Guerbet Co., France). The image quality of source images and 3D reconstructions was evaluated by two examiners using a 3-point scale.
Results:
Large vessels (portal vein, left and right branch of the portal vein, superior mesenteric vein, splenic vein) are visualized well or adequately in 80-93% of the cases, while this was achieved in only 53-60% of the small veins (vessels of the first order emptying into the superior mesenteric vein and the spleen). Venous arcades of the mesenterium are not visible by this technique.
Conclusion:
SPIO-supported MRA of the portal venous system yields usable results in the majority of patients. A possible indication is preinterventional angiography together with an SPIO examination for the detection of focal liver lesions.