Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Application of draft European Commission reference levels to a regional CT dose survey
J Clarke1, K Cranley, J Robinson
1Department of Radiology, Antrim Area Hospital, Northern Ireland.
Abstract:
A survey of CT doses in Northern Ireland in the period between October 1995 and March 1997 was carried out. The survey included all but one of the 10 scanners in use at the time, and, additionally, two others that were replacement machines. The method used was to study standard protocols and calculate doses to the NRPB mathematical phantom, so that a direct comparison could be made with other surveys carried out in a similar fashion elsewhere. The survey addressed the patient radiation dose but not image quality or clinical outcomes. It is estimated that in Northern Ireland the contribution to collective dose to the population from CT is about 40% of that from all medical X-rays. The proposed European Commission reference quantities, weighted CT dose index and dose-length product were computed and their potential use evaluated. A full study of mean values of effective dose per examination revealed the average dose per examination was not significantly different from that found in the 1989 UK survey, although several procedures gave rise to doses that were high enough to be investigated with a view to justification or reduction. One of the scanners was found to give consistently high doses. It is likely that a revision of the mAs values used on this scanner will produce a significant reduction in patient doses without compromising image quality. When compared with the draft EC reference levels, fewer procedures were found to have excessively high dose values. The proposed EC reference levels would therefore be useful for continual monitoring of CT dose status, but do not appear to provide as comprehensive an assessment of patient exposure as that given by consideration of effective doses.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT