Related Experiment Video
Updated: Oct 17, 2026

Hypercapnic Hyperventilation to Accelerate Emergence from Inhaled Volatile Anesthetics: A Practical Method Using Standard Hospital Equipment
Published on: June 26, 2026
Biologically variable ventilation prevents deterioration of gas exchange during prolonged anaesthesia
W A Mutch1, G M Eschun, S E Kowalski
1Department of Anaesthesia, Faculty of Medicine, University of Manitoba, Winnipeg, Canada.
Abstract:
We have studied the time course of changes in gas exchange and respiratory mechanics using two different modes of ventilation during 7 h of isoflurane anaesthesia in pigs. One group received conventional control mode ventilation (CV). The other group received biologically variable ventilation (BVV) which simulates the breath-to-breath variation in ventilatory frequency (f) that characterizes normal spontaneous ventilation. After baseline measurements with CV, animals were allocated randomly to either CV or BVV (FIO2 1.0 with 1.5% end-tidal isoflurane). With BVV, there were 376 changes in f and tidal volume (VT) over 25.1 min. Ventilation was continued over the next 7 h and blood gases and respiratory mechanics were measured every 60 min. The modulation file used to control the ventilator for BVV used an inverse power law frequency distribution (I/fa with a = 2.3 +/- 0.3). After 7 h, at a similar delivered minute ventilation, significantly greater PaO2 (mean 72.3 (SD 4.0) vs 63.5 (6.5) kPa) and respiratory system compliance (1.08 (0.08) vs 0.92 (0.16) ml cm H2O-1 kg-1) and lower PaCO2 (6.5 (0.7) vs 8.7 (1.5) kPa) and shunt fraction (7.2 (2.7)% vs 12.3 (6.2)%) were seen with BVV, with no significant difference in peak airway pressure (16.3 (1.2) vs 15.3 (3.7) cm H2O). A deterioration in gas exchange and respiratory mechanics was seen with conventional control mode ventilation but not with BVV in this experimental model of prolonged anaesthesia.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...