Related Experiment Video
Updated: Sep 4, 2026

Bio-layer Interferometry for Measuring Kinetics of Protein-protein Interactions and Allosteric Ligand Effects
Published on: February 18, 2014
Binding kinetics of soluble ligands to transmembrane proteins: comparing an optical biosensor and dynamic flow
G Boulla1, C Randriamampita, G Raposo
1Laboratoire d'Immunologie Cellulaire, Paris, France.
Background:
The kinetics of protein-protein interactions can be monitored with optical biosensors based on the principles of either surface plasmon resonance or mirror resonance. These methods are straightforward for soluble proteins, but not for proteins inserted in the plasma membrane.
Methods:
We monitored with an IASys biosensor system, based on a resonant mirror: (1) the binding of cells to an immobilized ligand, (2) the binding of a soluble ligand to immobilized cells, and (3) the binding of a soluble ligand to immobilized plasma membrane vesicles. For comparison, the kinetics of fluorescent antibody binding to intact cells were measured by dynamic flow cytometry.
Results:
With an optical biosensor, the useful configuration is the one based on immobilized plasma membrane vesicles. However, signals can be detected only for very abundant binding sites (>10(6) per cell). Dynamic flow cytometry allows the accurate determination of the k(on) and k(off) of antibody binding. The sensitivity of the method is two orders of magnitude better than with an optical biosensor.
Conclusions:
Although biosensors constitute a method of choice for measuring the interactions between soluble proteins, they are not well suited for measuring the interaction between soluble proteins and membrane-embedded proteins. On the contrary, flow cytometry is well suited for such an application, when it is used in a dynamic mode.
More Related Videos
14:09Fluorescence Biomembrane Force Probe: Concurrent Quantitation of Receptor-ligand Kinetics and Binding-induced Intracellular Signaling on a Single Cell
Published on: August 4, 2015
08:26Analyzing the Interaction of Fluorescent-Labeled Proteins with Artificial Phospholipid Microvesicles using Quantitative Flow Cytometry
Published on: April 6, 2022
Related Concept Videos
The Equilibrium Binding Constant and Binding Strength
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...