Related Experiment Video
Updated: Aug 15, 2026

A Protocol for Comprehensive Assessment of Bulbar Dysfunction in Amyotrophic Lateral Sclerosis (ALS)
Published on: February 21, 2011
Effect of compression ratio on speech recognition and speech-quality ratings with wide dynamic range compression
1Department of Speech and Hearing Sciences, University of Washington, Seattle, USA. ktboike@u.washington.edu
Abstract:
This project examined the effect of varying compression ratio on speech recognition and quality. Both listeners with mild-to-moderate sensorineural hearing loss and a control group of listeners with normal hearing participated. Test materials were sentences from the Connected Speech Test (R. M. Cox, G. C. Alexander, & C. Gilmore, 1987) which were digitally processed with linear amplification and wide dynamic range compression amplification with 3 compression ratios. Speech-recognition scores were obtained with sentences in quiet and in noise at a 10-dB signal-to-noise ratio for each amplification condition. Additionally, the participants rated each amplification condition in terms of clarity, pleasantness, ease of understanding, and overall impression. Results indicated that, for speech in quiet, compression ratio had no effect on speech-recognition scores; however, speech-quality ratings decreased as compression ratio increased. For speech in noise, both speech-recognition scores and ratings decreased with increasing compression ratio for the listeners with hearing loss. These results suggest that selection of compression ratio on the basis of speech-quality judgments does not compromise speech recognition.
Related Concept Videos
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated. For...
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and hence a...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Characteristics of Practical Op Amps
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Design Example: Vintage Mixing Console
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
Applications of Logarithms

