Related Experiment Video
Updated: Jan 24, 2026

Author Spotlight: Enhancing Success of Ultrasound-Guided Neuraxial Anesthesia in Cases with Difficult Anatomy
Published on: January 31, 2025
Transvaginal hysterosalpingo-contrast sonography (HyCoSy) compared with chromolaparoscopy
S Tanawattanacharoen1, S Suwajanakorn, B Uerpairojkit
1Department of Obstetrics and Gynaecology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
Objective:
To compare the efficacy and safety of HyCoSy with chromolaparoscopy for the diagnosis of tubal occlusion and uterine abnormalities.
Methods:
Sixty infertile women in whom the cause of infertility was thought to be tubal occlusion or uterine abnormalities and who satisfied the inclusion and exclusion criteria as specified in the study protocol were included. HyCoSy was performed during the first half of the menstrual cycle at least 24 hours prior to chromolaparoscopy. The results from both HyCoSy and chromolaparoscopy were compared in assessing tubal occlusion and uterine pathology.
Results:
For the evaluation of fallopian tubes, we found corresponding results between HyCoSy and chromolaparoscopy in 80.0%. The agreement between both procedures in assessing the uterine pathology was 80.4%. Twenty-two women experienced adverse events. The most common complaint was pelvic pain. Other events encountered were: nausea (3 women) and vaginal bleeding (2 women). All events were thought to be not related to the study drug.
Conclusion:
HyCoSy showed good diagnostic performance in the evaluation of the fallopian tubes and uterus in infertile women. The adverse events reported in this study are minor and procedure-related (catheter insertion) rather than the trial substance.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Comparing the Survival Analysis of Two or More Groups
Comparing Experimental Results: Student's t-Test
Comparative Excretory Systems
Comparing Intermolecular Forces: Melting Point, Boiling Point, and Miscibility
Temporary attractive forces like dispersion are present in all molecules, whether they are polar or nonpolar. They...