Related Experiment Video
Updated: Oct 16, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Discrimination and thermal degradation of toxaphene compounds in capillary gas chromatography when using
H R Buser1, P Haglund, M D Müller
1Swiss Federal Research Station, Wädenswil. hans-rudolf.buser@faw.admin.ch
Abstract:
Technical toxaphene and a 22-component Reference Mixture were analyzed using capillary gas chromatography with split/splitless injection (SSL) and on-column injection (OC). In both techniques, electron-capture, negative ionization mass spectrometry (ECNI-MS) was used for detection of chlorobornanes, chlorocamphenes and related compounds. Significant discrimination of highly chlorinated congeners was observed as a result of incomplete transfer of these compounds from the vaporizer to the analytical column when using SSL. This resulted in a much lower response for nona- and decachloro congeners than when using OC. In addition, several toxaphene components, especially the chlorobornanes with gem dichloro substitution on the six-member carbon ring, undergo thermal degradation when using SSL. Some of these congeners are major components of technical toxaphene, but generally are not present, except at low concentrations, in environmental and biological samples. Therefore, technical toxaphene may be discriminated and/or degraded differently than toxaphene compounds in environmental samples when using SSL. This results in significant bias of the quantitative data when using the technical material as a reference. OC suffers much less from these deficiencies and, therefore, is a preferable technique for toxaphene analysis.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...