Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Left ventricular apex ablation decreases the upper limit of vulnerability
N Chattipakorn1, P C Fotuhi, X Zheng
1Division of Cardiovascular Disease, Department of Medicine, University of Alabama, Birmingham, USA. toon@crml.uab.edu
Background:
After shocks with an approximately 50% probability of success for the upper limit of vulnerability (ULV(50)) of strength, the first few activations appear focally on the epicardium at almost the same site at the left ventricular (LV) apex in both successful and failed induction of ventricular fibrillation (VF). We tested the hypothesis that subendocardial ablation at this early site would decrease the shock strength required for the ULV(50).
Methods And Results:
Ten S1 stimuli were delivered from the right ventricular apex at a 300-ms coupling interval in 5 pigs. Biphasic shocks were delivered from right ventricular-superior vena cava electrodes after the last S1 stimulus. The ULV(50) was determined using an up/down protocol with T-wave scanning. Radiofrequency ablation was performed endocardially at the apical LV. The ULV(50) was determined again 30 minutes after ablation. To determine the importance of the ablation region, this protocol was repeated in another 5 pigs with ablation at the LV base. Delivered voltage (401+/-60 versus 323+/-50 V) and energy (11+/-3 versus 7+/-2 J) for the ULV(50) were significantly decreased after LV apex ablation by 19% and 34%, respectively. However, no difference existed in ULV(50) before and after LV base ablation. Lesions at both the LV apex and base were subendocardial and ranged from 0.8 to 1.1 cm in diameter.
Conclusions:
Subendocardial ablation at the apical LV markedly decreases ULV(50), which suggests that the activation originating from this postshock early site is responsible for VF initiation and that interventions to electrically silence this site can influence the outcome of VF induction by ULV shocks.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Mitral Stenosis I: Introduction
Aortic Regurgitation III: Medical Management
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Cardiomyopathy V: Interprofessional Care