Effects of sample size on the noise floor and distortion product otoacoustic emissions

R C Beattie1, A Ireland

  • 1Department of Communicative Disorders, California State University, Long Beach 90840, USA.

Related Concept Videos

Sample Size Calculation01:19

Sample Size Calculation

Knowledge of the sample size is the first requirement to conduct random sampling or an experiment. The sample size is the total number of units, observations, or groups (in some cases) used to get the data to estimate a population parameter. As the name suggests, the sample size is that of the sample drawn from the population and differs from the population size.
The sample size for the given experiment or sampling effort is fundamental to any study design. Sample size decides the number of...
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
Sampling Methods: Overview01:06

Sampling Methods: Overview

A sample refers to a smaller subset representative of a larger population. In analytical chemistry, studying or analyzing an entire population is often impractical or impossible. Therefore, samples are used to draw inferences and generalize the whole population. The sampling method selects individuals or items from a population to create a sample. Standard sampling methods include random, judgemental, systematic, stratified, and cluster sampling. 
In analytical chemistry, the choice of sampling...
Contaminants and Errors01:16

Contaminants and Errors

Effective sample preparation is crucial for accurate and reliable laboratory analysis. During this process, two significant sources of error can arise: concentration bias from improper sample splitting and contamination caused by methods used to reduce particle size, such as grinding or homogenization. Identifying and minimizing these potential errors is crucial to ensuring the validity of the analysis.
Another key consideration is determining the appropriate number of samples required to...
Aliasing01:18

Aliasing

Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original signal...
Upsampling01:22

Upsampling

Managing signal sampling rates is essential in digital signal processing to maintain signal integrity. A decimated signal, characterized by a reduced frequency range due to its lower sampling rate, can be upsampled by inserting zeros between each sample. This upsampling process expands the original spectrum and introduces repeated spectral replicas at intervals dictated by the new Nyquist frequency. To refine this zero-inserted sequence, it is passed through a lowpass filter with a cutoff...