Breath interval as a measure of dynamic opioid effect
J A Smart1, E J Pallett, D J Duthie
1University Department of Anaesthesia, Glenfield Hospital, Leicester, UK.
Abstract:
We measured breath interval to characterize the time course of opioid effect in anaesthetized patients breathing spontaneously during knee replacement surgery with concurrent regional nerve blockade. Breath interval was recorded before and after a single dose of fentanyl 0.75 microgram kg-1 i.v. Breath interval was measured between the start of successive inspirations, identified by a decrease in carbon dioxide concentration, sampled at the laryngeal mask connection. Nineteen patients were admitted to the study, of whom nine were withdrawn (there was a recording failure for one patient, five patients had inadequate block and three were excessively depressed by the fentanyl). Using MKMODEL software, the mean (SD) dynamic elimination half-life and dynamic mean brain residence time of fentanyl were 15.3 (7.8) and 24.1 (8.1) min, respectively. The times to detection of change from baseline, and peak effect of fentanyl on breath interval were 0.9 (0.6) and 5.2 (1.4) min, respectively. Breath interval increased from 2.9 (1.0) s to a maximum of 9.0 (5.7) s. There were no differences between the time course of changes in breath interval and end-tidal carbon dioxide concentrations. End-tidal carbon dioxide concentrations increased from a baseline of 6.6 (0.9)% to a peak of 8.2 (0.8)%. Breath interval was a useful and reproducible method of monitoring the duration of opioid effect in anaesthetized patients breathing spontaneously when surgical stimulation was not affecting the CNS. The data provide information on the duration of action of fentanyl and could guide dosage.
More Related Videos
06:13Combining a Breath-Synchronized Olfactometer with Brain Simulation to Study the Impact of Odors on Corticospinal Excitability and Effective Connectivity
Published on: January 19, 2024
08:44Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Related Concept Videos
Respiratory Volumes and Capacities I
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Opioid Analgesics: Morphine and Other Natural Cogeners
Opioid Analgesics: Synthetic and Semisynthetic Opioids
Pharmacokinetic–Pharmacodynamic Relationship: Duration of Dose-Effect Relationship