Related Experiment Video
Updated: Oct 13, 2026

In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Reliable gas chromatographic-mass spectrometric method combined with a headspace autosampler for isoflurane
Abstract:
Isoflurane is a nonflammable, liquid, volatile inhalation anesthetic administered by vaporizing. Although it is now commonly used, fatal cases resulting from its abuse or misuse have been reported. A combined system of a gas chromatograph-mass spectrometer and a headspace autosampler is therefore proposed for the detection of blood isoflurane. This analytic method showed sharp and well separated peaks, and revealed a good linear relationship (r=0.9994) with a function of y = 7.3768x - 0.0222 at concentrations between 18.7 and 299.2 microg/ml. The limits of detection and quantitation of this method were 1.2 and 4.7 microg/ml, respectively. The within- and between-run precision for spiked samples, assessed by the coefficient of variations, ranged from 1.7 to 10.0% and from 4.1 to 12.8%, respectively. The within- and between-run accuracy, assessed by errors from theoretical values, were 2.2-7.8% and 2.4-9.6%, respectively. In addition, practical sample analysis showed a good applicability, with a within-run precision rate of 5.6 to 7.7% and a between-run precision rate of 5.2-10.6%. In summary, the present work presents a valid alternative for blood isoflurane analysis.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
04:19An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...