Related Experiment Videos
Clinical comparison of two total ankle replacements
1Wrightington Hospital NHS Trust, Wigan, Lancashire, United Kingdom. plrwood@yahoo.com
Foot & Ankle International
|August 5, 2000
Summary
The cementless Scandinavian Total Ankle Replacement (STAR) prosthesis showed better long-term results than the cemented Thompson Parkridge Richards (TPR) prosthesis in rheumatoid arthritis patients. STAR implants remained satisfactory, while TPR components frequently showed loosening.
Area of Science:
- Orthopedic Surgery
- Rheumatology
- Biomaterials Science
Background:
- Rheumatoid arthritis (RA) frequently affects the ankle joint, necessitating surgical intervention.
- Total ankle replacement (TAR) aims to alleviate pain and restore function in RA patients with severe ankle arthritis.
- Comparing cemented and cementless prosthesis designs is crucial for optimizing long-term outcomes.
Purpose of the Study:
- To compare the clinical and radiographic outcomes of the cemented Thompson Parkridge Richards (TPR) and cementless Scandinavian Total Ankle Replacement (STAR) prostheses.
- To evaluate the survivorship and complication rates of these two TAR designs in rheumatoid arthritis patients.
Main Methods:
- A retrospective comparison of 14 consecutive total ankle arthroplasties in 12 rheumatoid arthritis patients.
- Patients were treated by a single surgeon, receiving either cemented TPR or cementless STAR prostheses.
- Follow-up assessment included clinical evaluation and radiographic analysis at a minimum of five years post-surgery.
Main Results:
- Four out of six cemented TPR tibial components showed radiographic loosening within two years.
- Two cases with TPR loosening required conversion to ankle fusion.
- All cementless STAR prostheses demonstrated satisfactory clinical and radiographic results at the five-year follow-up.
Conclusions:
- Cementless STAR total ankle replacement demonstrates superior radiographic stability and clinical outcomes compared to cemented TPR prosthesis in rheumatoid arthritis patients.
- The high rate of tibial component loosening with the cemented TPR design suggests potential limitations for long-term efficacy in this patient population.
- Cementless designs may offer a more durable solution for total ankle replacement in rheumatoid arthritis, warranting further investigation.