Measurement of oxygen saturation in venous blood by dynamic near infrared spectroscopy
Related Experiment Video
Updated: Oct 13, 2026

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
M Nitzan1, A Babchenko, B Khanokh
1Department of Physics/Electro-Optics, Jerusalem College of Technology, Israel. nitzan@mail.jct.ac.il
Abstract:
A method for the measurement of oxygen saturation in the venous blood, SvO2, based on optical measurements of light absorption in the infrared region is presented. The method consists of applying relatively low external pressure of 25 mm Hg on the forearm, thereby increasing the venous blood volume in the tissue, and comparing the light absorption before and after the external pressure application. SvO2 has been determined from light absorption measurements in two wavelengths, before and after the pressure application, using a formula derived for two adjacent wavelengths. The method has been applied to the hands and fingers of 17 healthy male subjects, using wavelengths of 767 and 811 nm. SaO2, the oxygen saturation for arterial blood, was also obtained from photoplethysmographic measurements in these two wavelengths (pulse oximetry) using the same formula. The mean (+/- SD) value of SaO2 was 94.5% (+/- 3.0). The mean value of SvO2 was 86.2% (+/- 4.1) for the finger and 80.0% (+/- 8.2) for the hand. These SvO2 values are reasonable for the finger and the hand where arterio-venous anastomoses exist. The method enables the measurement of SvO2 in the limbs, a parameter which is related to tissue blood flow and oxygen consumption.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:44Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...