Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: I. Analysis and compensation of eddy currents
Y De Deene1, C De Wagter, W De Neve
1Radiotherapy and Nuclear Medicine, University Hospital of Gent, Belgium. yves.dedeene@rug.ac.be
Abstract:
In BANG gel dosimetry, the spin-spin relaxation rate, R2 = I/T2, is related to the radiation dose that has been delivered to the gel phantom. R2 is calculated by fitting the pixel intensities of a set of differently T2-weighted base images. In gel dosimetry for radiotherapy, an accuracy of 5% in dose and 3 mm spatially, whichever is lower, is the objective. Therefore, possible sources of artefacts must be considered and dealt with. To obtain a set of base images a multiple spin-echo sequence is used. However, in a conventional MR scanner eddy currents will be provoked by switching the imaging gradients. As the eddy currents change in the course of the sequence, the net magnetization will be affected accordingly. Hence, eddy currents may have a significant influence on the quantitative R2 images themselves as well as on their slice position. In this study, we report an analysis of the eddy currents as they appear in the multiple spin-echo sequence. Eddy currents are measured using a frequency shift method resulting in eddy current field maps. The related geometrical displacements are obtained by use of a pyramidal phantom. The R2 versus dose relation is determined in the three main directions of the magnet, revealing a dependence of the measured R2 on slice orientation. The time course of eddy currents is then used in a computer simulation to estimate the effects they produce in the recorded R2 images. A compensation method for eddy current effects in multi-echo T2 mapping is described.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...